EXPERIMENTALANDANALITICALSTUDYOFLOADANDSLIPCAPACITYOF HEADEDSTUDCONNECTORSINCOMPOSITESLABSFORBUILDINGS
Keywords:
comprehensive, notable, variances.Abstract
The behavior of shear connections in
composite beam construction has been
determined by a comprehensive experimental
examination conducted in compliance with
EC4-1-1Annex B.2. In order to illustrate the
steel-concrete
composite
ultimate
strength
behavior
construction's
from the
component level to the structural level, six
push-out experiments were published. Push
out tests were used to examine the specimens
while
varying
constructive
parameters.
Longitudinal and transverse steel sheeting
types and positions were varied for headed
stud
connectors
with
d=19mm and
hsc=100mm. Additionally, there were
variations in the number of shear connections
in the cross section (1 or 2) and the welding
process, both via deck welding and with holes.
We re-adopted concrete with grade C25/30,
which is the commonly used grade, and
reinforcing with a low percentage. When the
results of load capacity were compared to the
intended load capacity as per EC4-1-1 (6.6.3
and 6.6.4), there were sometimes notable
variances.